Compliance Test of Percentage Depth Dose (PDD) Using LINAC Machine Brand Electa Precise against American Association of Physicists in Medicine (AAPM) PDD with Electron Beam Energy Variation at Radiotherapy Installation RSUP Prof. Ngoerah in Denpasar

Naumi Paramita Putri Monicasari

Department of Physics, Udayana University, Bali, Indonesia.

Ni Nyoman Ratini

Department of Physics, Udayana University, Bali, Indonesia.

I. Wayan Balik Sudarsana

Central General Hospital Prof. Dr. I. G. N. G. Ngoerah, Denpasar, Bali, Indonesia.

Ida Bagus Made Suryatika

Department of Physics, Udayana University, Bali, Indonesia.

Ir. Putu Suardana

Department of Physics, Udayana University, Bali, Indonesia.

I. Gusti Agung Widagda

Department of Physics, Udayana University, Bali, Indonesia.

Anak Agung Ngurah Gunawan *

Department of Physics, Udayana University, Bali, Indonesia.

Rozi Irhas

Central General Hospital Prof. Dr. I. G. N. G. Ngoerah, Denpasar, Bali, Indonesia.

*Author to whom correspondence should be addressed.


Abstract

The purpose of the study was to determine the value of PDD against energy variations in the electron beam using the Elekta Precise Brand LINAC aircraft, and to determine the suitability of the PDD value against energy variations in the electron beam with the standards set by AAPM. PDD value data obtained from the results of research using Sun Nuclear Dosimetry Software (SNC Dosimetry). The results of the study will then be compared with the standard Tolerance value set by AAPM of a maximum of 2%. From the deviation value of each 4 MeV energy is 1.1% - 1.8%, 6 MeV energy is 1.1% - 1.6%, and 8 MeV energy is 1.0% - 1.2%, the deviation error at 4, 6, and 8 MeV energy is in accordance with the tolerance limit set by AAPM which is 2%. So that the Elekta Precise LINAC machine at the Radiotherapy Installation of Prof. Ngoerah Denpasar Hospital is feasible to operate to receive patients.

Keywords: LINAC, electron, energy, PDD, deviation


How to Cite

Monicasari , Naumi Paramita Putri, Ni Nyoman Ratini, I. Wayan Balik Sudarsana, Ida Bagus Made Suryatika, Ir. Putu Suardana, I. Gusti Agung Widagda, Anak Agung Ngurah Gunawan, and Rozi Irhas. 2023. “Compliance Test of Percentage Depth Dose (PDD) Using LINAC Machine Brand Electa Precise Against American Association of Physicists in Medicine (AAPM) PDD With Electron Beam Energy Variation at Radiotherapy Installation RSUP Prof. Ngoerah in Denpasar”. Asian Journal of Medicine and Health 21 (10):226-32. https://doi.org/10.9734/ajmah/2023/v21i10897.